Verified method references · v0.6
Foreign numerical limits are not adopted as Albanian law. No numerical limits are taken from inaccessible clauses.
Car park design ↗
Institution of Structural Engineers · First published June 2023, version 1.0 · Public contents: 5.3.10 Vehicle ramp requirements; 5.4.4 Vehicle ramps
Parking layout reference bibliography only. Public front matter/contents verified; full technical clauses were not accessible. No numerical ramp limits adopted from this publication.
UK professional guidance; not automatically applicable in Albania · Advisory bibliography, no adopted design limit
Safety Effects of Horizontal Curve and Grade Combinations on Rural Two-Lane Highways ↗
US Federal Highway Administration · FHWA-HRT-13-077, January 2014 (archived) · Chapter 2, vertical alignment discussion
Parabolic transitions between constant grades; grade measured using horizontal projected distance; distinction between crest and sag. Highway design-speed limits are not used for parking ramps.
United States highway research; methodological only for this tool · Technical reference, not Albanian regulation
About Checking Vertical Clearances ↗
Autodesk · Vehicle Tracking 2024 documentation · Vertical Clearance drive mode
Need to account for ground/overhead envelopes and suspension/loading uncertainty. Our implementation checks ground only and is explicitly Partial / Not Verified.
Software methodology; no statutory jurisdiction · Technical reference
Unit Details: Front and Rear Axles ↗
Autodesk · Vehicle Tracking 2022 documentation · Axle steering and wheel dimensions
Distinguish steered front and fixed rear axles; enter real axle dimensions and steering limits. This tool uses a no-slip bicycle approximation, not a full Ackermann wheel/suspension solver.
Software methodology; no statutory jurisdiction · Technical reference
Vehicle Check: prescribed front axle; integrated rear-heading bicycle kinematics. Four undeformed tyres with bounded independent vertical suspension, iterative rigid pitch/roll. Editable extruded underside side profile, actual triangle-overlap clearance checked at sampled poses. Unsupported entry/exit contacts are reported. No load/dynamic/suspension stiffness or overhead model; no continuous swept-path guarantee; no two-way simulation. Assumed presets require real manufacturer dimensions.
Reference 90° sample dimensions are interpreted in cm (500 = 5 m; inner radius 2.50 m).
Profiles use z(x) = z0 + g1·x + (g2−g1)·x²/(2L), with grades as ratios. Main grade solves the required rise exactly. K = L / |grade change in %|, in m / %. Floors and transition lengths are editable.
TxDOT · vertical-curve mathematics ↗
FHWA · grade transitions and K ↗
VA Parking Design Manual · section 7-3 ↗
Roadway sources support the mathematics only; highway design speeds and K limits are not imported into indoor parking design. The VA guide flags floor/ramp transitions and wheel-line clearance. These are methodological references, not Albanian regulations or project approval.
The surface interpolates analytical alignments over a harmonic longitudinal-progress field. User points apply constrained FEM residual corrections on conforming triangles. Curves are exact in plan/DXF, chord-approximated in the surface. Point elevations are honored within 0.00001 m. Cross slope is a sampled edge-to-edge average. Profiles show analytical alignments; the reference also shows the actual sampled mesh. No full vehicle swept-path, chassis clearance, drainage or regulatory verification is implemented.
DXF import remains limited to two open XY LWPOLYLINE boundaries with m/cm/mm units.